VNF1-8040 NF Membrane
Effective membrane area: 37.2㎡
Desalination rate: 30-60%
SO₄²⁻ Removal rate: 98%
Water production: 37.9 m³/day
Maximum water inlet pressure: 4.1 Mpa
Influent PH value range: 3-10
Maximum inlet water turbidity: 1.0 NTU
VNF1-8040 NF Membrane
The VNF1-8040 nanofiltration membrane is an 8-inch industrial NF element manufactured by Vontron, designed for large-scale water treatment systems requiring higher permeate flow and stable divalent salt rejection.
Compared to 4-inch elements, the 8040 configuration provides significantly greater membrane area and output capacity, making it ideal for municipal, industrial, and high-volume process water applications.
VNF1-8040 is commonly used as a cost-effective alternative to FilmTec™ NF270-8040 (by DuPont) in industrial projects.
Key Technical Specifications (Industrial Grade Focus)
| Item | DuPont FilmTec NF270-8040 | Vontron VNF1-8040 |
|---|---|---|
| Membrane Type | Nanofiltration (NF) | Nanofiltration (NF) |
| Standard Element Size | 8″ × 40″ | 8″ × 40″ |
| Effective Membrane Area | ~400 ft² (≈ 37.2 m²) | ~400 ft² (≈ 37.2 m²) |
| Typical Permeate Flow | ~10,000 GPD (≈ 37.9 m³/day) | ~10,000 GPD (≈ 37.9 m³/day) |
| Salt Rejection (MgSO₄) | ≥ 97% | ≥ 98% |
| Salt Rejection (NaCl) | 20-50% | 30-60% |
| Test Operating Pressure | ~70 psi (0.48 MPa) | ~100 psi (0.69 MPa) |
| Maximum Operating Pressure | 600 psi (4.1 MPa) | 600 psi (4.1 MPa) |
| Maximum Operating Temperature | 45 °C | 45 °C |
| Operating pH Range | Continuous: 2–11(Cleaning: 1–12) | Typically 2–11 (Cleaning: 1–12) |
| Output Water SDI | ≤ 3 | ≤ 3 |
| Free Chlorine Tolerance | < 0.1 ppm (must be removed) | < 0.1 ppm (must be removed) |
| Typical Applications | Drinking water treatment, organic matter (TOC) removal, partial softening | Drinking water, industrial process water, bottled water, wastewater polishing |
| System Compatibility | Standard 8040 membrane housings | Fully compatible with standard 8040 membrane housings |
| Price | About $1,000/pcs | About $700/pcs |
Note: The above data are from Dow's official website and Vontron's official website.
🔗 Read our detailed blog: DOW NF270 Alternative: Why Vontron NF Membrane Is a Smart Replacement
Why Choose 8-Inch NF Instead of 4-Inch?
- Higher membrane area per element
- Reduced system footprint per m³ capacity
- Lower installation cost per unit of water produced
- Fewer pressure vessels required
- Ideal for skid-mounted and containerized systems
Industrial Performance Advantages of VNF1-8040
- High-flux design for large-scale plants
- Stable divalent ion rejection (softening + sulfate removal)
- Partial monovalent salt passage (balanced mineral profile)
- Energy-efficient compared to RO
- Compatible with standard 8040 pressure membrane housings
- Reliable long-term operation in continuous systems
Comparison of Recommended Membranes (FilmTec™ NF270-8040 vs Vontron VNF1-8040)
| Application Requirements | Recommended Membrane |
|---|---|
| Large-scale municipal water treatment with high daily output | NF270-8040 (higher flux, globally established brand) |
| Industrial process water or bottled water systems requiring stable performance | VNF1-8040 (high cost-performance ratio) |
| Tight budget & large-volume membrane supply projects | VNF1-8040 |
| Projects requiring long-term stability, brand assurance & international compliance | NF270-8040 |
| EPC / Engineering contracts needing international standard elements | NF270-8040 |
| Replacement or retrofit of existing 8040 membrane systems | VNF1-8040 |
💡Conclusion:
✅ NF270-8040 is positioned as the premium, internationally recognized solution preferred in EPC / regulated markets.
✅ VNF1-8040 is positioned as the cost-effective industrial alternative, especially when membrane quantity is large or budget is sensitive.
Typical Industrial Applications
Municipal water treatment plants
Industrial process water systems
Boiler feed water pretreatment
Food & beverage manufacturing lines
Mining & chemical industries
Water reuse and zero-liquid-discharge (ZLD) pre-treatment

requently Asked Questions (FAQ) – VNF1-8040 Membrane
Q: What is the difference between VNF1-4040 and VNF1-8040?
A: The 8040 version has a larger diameter (8 inches) and significantly higher membrane area, making it suitable for industrial-scale systems with higher daily output requirements.
Q: Is VNF1-8040 compatible with NF270-8040 systems?
A: Yes. It is designed to fit standard 8-inch 8040 pressure vessels and can be used as a replacement in compatible NF systems.
Q: Do you supply genuine Vontron 8040 membranes?
A: Yes. All VNF1-8040 membranes from Xi'an Ink-blue Company are supplied with original anti-counterfeiting verification codes.
Q: Can you supply FilmTec™ NF270-8040 as well?
A: Yes. Upon request, we can supply FilmTec™ NF270-8040 membranes to match systems or meet project requirements.
Hot Tags: VNF1-8040 NF Membrane, China VNF1-8040 NF Membrane manufacturers, suppliers, factory, nf membrane for magnesium removal, nf membrane for iron removal, nf membrane for pharmaceutical industry, nf membrane for calcium removal, nf membrane for chemical industry, nf membrane for variable pressure applications
Previous
Vontron NF 4040 MembraneYou Might Also Like
Send Inquiry